HE 5711 - Valve Control Unit - 8 Valves

* 8 valve outputs 24 V DC / max. 1 A
* 2 modes: permanent- or full cycle cleaning
* Operational display for all valves (LEDs)
* Mains supply 230 / 115 V AC, 24 V DC
* Transformer adaptable for different types of valves

The valve control unit HE 5711 with micro- processor is used for pulse activation of solenoid valves in industrial dust filter control systems.

Build in functions:
- Valve number, adjustment of number of valves 1 - 8 with rotary code
switch
- Permanent cleaning, adjustment of pulse- and pause time per potentiometer
- Cycle cleaning, adjustment of full cycles 1 - 10 with rotary code switch
- Start push-button, the adjusted cleaning cyles are excecuted
- Test push-button, the next valve will be activated

Flexible assembly as:
- Circuit board for cabinet installation with screws
- DIN-rail carrier version
- Plastic housing with EX ATEX approbation

 

 

HE 5721 - Filter Controller max. 12/24 Valves

* 12 valve outputs 24 V DC / max. 1 A
Option: up to 24 valve outputs
* 2 relay outputs 250 V AC / 5 A
* Time- / ΔP-mode (with pause time)
* Operational- / error display of all valves
* Mains supply 230 V AC, 30 VA
(Option: 115 V AC or 24 V DC)
* Post-cleaning 1-12 cycles
* Valve monitoring with pressure switch (option)
* 3-digit multi functional display

ΔP-Controller:
* ΔP-measuring ranges between 0 .. 25 or 0 .. 500 mbar
* 1 relay ΔP-alarm 250 V AC / 5 A
* Analog output 0(4)-20 mA on the base board

The HE 5721 filter controller (timer) is used for pulse activation of solenoid valves in air pollution control systems. The controller features various control- and monitoring functions. The ΔP-controller is included in this version.
The cleaning process can be controlled by time intervalls or DP-depended with switching thresholds resp. automatic pause-time control. The valve current is checked for open loops and short-circuits.
A mechanical valve monitoring with an optional pressure switch is possible.
The device is suitable for explosion zone 22.

 

 

HE 5721FP - Filter Controller max. 12/24 Valves
Version Front Panel

 

 

 

 

 

Functionality like upper version without frontpanel

 

 

 

 

 

 

 

 

HE 5712/31 - Filter Controller 8/16/32/48/64 Valves

* 16 valve outputs 24 V DC / max. 1 A
Option: extension by slave units up to 64 valve outputs
* relay output 250 V AC / 5 A
* Time- / ΔP-mode (with pause time)
* Operational- / error display of all valves
* Mains supply 230 V AC, 30 VA
(Option: 115 V AC or 24 V DC)
* Post-cleaning 1-12 cycles
* Valve monitoring
* 3-digit multi functional display

ΔP-Controller HE 5409 extern:
* ΔP-measuring ranges 0 .. 25 or 0 .. 50 mbar

The HE 5731 filter controller (timer) is used for pulse activation of solenoid valves in air pollution control systems. The controller features various control- and monitoring functions. The ΔP-controller is placed as an extern unit (HE 5409) in this version.
The cleaning process can be controlled by time intervalls or ΔP-depended with switching thresholds resp. automatic pause-time control. The valve current is checked for open loops and short-circuits.
The device is suitable for explosion zone 22.

 

 

 

 

5731 240 x

HE 8991 - Filter Controller max. 20/60/99 Valves

Technical details avalible on request

 

 

 

 

 

 

 

 

 